Contents - Index


Import power system



Import a power system consisting of 3-phase BUS3 and LINE3 components discribed in a text file.
The elements could be separated with tab, comma, semi-colon, space, or user defined character.

File format:

Header {Any number of line describing the case. When importing the user is asked which line to start importing at}
NumBus NumBranch Frequency
Number; Name; Volt [kV]; VoltPU; VoltAng; PL [MW]; QL [MVar]; MOV; CoorCode; X; Y
:
From; To; Type; R1 [W/km]; X1 [W/km]; C1[mF/km]; R0 [W/km]; X0 [W/km]; C0[mF/km]; Length [km]
:

Name
Is there is a space in the name it must be enclosed by ' or "; "BUS 1"

CoorCode
0: Coordinates unknown; calculate by optimization. Not supported in v. 6.1
1: GPS coordinates (-90..90 deg).
2: Cartesian coordinates in arbitrary units.
The coordinates are recalculated to make the shortest line having a length of 100 pixels. Any (sensitive) GPS position data is not stored.

Type
0: Overhead line
1: Underground cable
2: Transformer 2-winding. Not supported in v. 6.1.
3: Transformer 3-winding. Not supported in v. 6.1.


Example

My First Power System; Test 20/2-2016
6 8 50
1 BUS1 132  0.99 0     0     0  0  2  1000 1000
2 BUS2 132  0.98 1.12  2   0.5  0  2  2000 2000
3 BUS3 132  0.98 -2.3  1  -0.1  0  2  1000 -1000
4 BUS4 132  0.98 -2.3  1  -0.1  0  2  5000 2000
5 BUS5 132  0.98 -2.3  1  -0.1  0  2  7000 3000
6 BUS6 132  0.98 -2.3  1  -0.1  0  2  4000 -2000
1 2 0  1.00  1.00 0.100  1.00  1.00 0.100  1.4142
1 3 0  1.00  1.00 0.100  1.00  1.00 0.100  2.000
2 4 0  1.00  1.00 0.100  1.00  1.00 0.100  3.000
2 6 0  1.00  1.00 0.100  1.00  1.00 0.100  4.4721
3 4 0  1.00  1.00 0.100  1.00  1.00 0.100  5.000
3 6 0  1.00  1.00 0.100  1.00  1.00 0.100  3.1623
4 5 0  1.00  1.00 0.100  1.00  1.00 0.100  2.2361
4 6 0  1.00  1.00 0.100  1.00  1.00 0.100  4.1231