Contents - Index


Support data



On the data page of the Support file dialog box you specify the data parameters of the support file; one line for each object data parameter.

The following table describes available parameter options:

Option Description
Name The name of the parameter. Used to identify the parameter in the Open Component dialog box. 12 character names are supported from ATPDraw v. 5 (6 char. earlier).
Default Initial value of parameter.
Units The unit of the data parameter displayed in the Open Component dialog (12 characters). The protected strings XOPT and COPT are replaced by mH/Ohm and mF/mS dependent on the users choice in ATP|Settings/Simulation. The protected string SOURCE is replace by Volt or Ampere dependent on the user's choice of source type.
Min Minimum value allowed. Put min=max to allow any value.
Max Maximum value allowed.
Param =1: A variable text string can be assigned to the data value. The values are assigned under ATP|Settings/Variables.
Digits Maximum number of digits allowed in the ATP file. When high precision is checked, $Vintage, 1 is enabled and Digits is split in two values for high and low precision. The Digits parameter is used only for MODELS and user specified components in $INCLUDE statement. 
Page Not in use

An error message will appear in the Open Component dialog box if a parameter value is out of range.